亚洲一区欧美在线,日韩欧美视频免费观看,色戒的三场床戏分别是在几段,欧美日韩国产在线人成

便攜式作物生長(zhǎng)監(jiān)測(cè)診斷儀性能試驗(yàn)
作者:
作者單位:

作者簡(jiǎn)介:

通訊作者:

中圖分類號(hào):

基金項(xiàng)目:

國(guó)家高技術(shù)研究發(fā)展計(jì)劃(863計(jì)劃)資助項(xiàng)目(2011AA100703)、江蘇省科技支撐計(jì)劃資助項(xiàng)目(BE2010395、BE2011351)、江蘇省省級(jí)現(xiàn)代服務(wù)業(yè)(軟件產(chǎn)業(yè))發(fā)展專項(xiàng)引導(dǎo)資金資助項(xiàng)目、江蘇省工業(yè)和信息產(chǎn)業(yè)轉(zhuǎn)型升級(jí)專項(xiàng)引導(dǎo)資金資助項(xiàng)目(物聯(lián)網(wǎng)專項(xiàng))、江蘇省農(nóng)業(yè)科技自主創(chuàng)新資助項(xiàng)目(SCX(12)3272)和江蘇高校優(yōu)勢(shì)學(xué)科建設(shè)工程資助項(xiàng)目(PADA)


Experiments on Performance of Portable Plant Growth Monitoring Diagnostic Instrument
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問(wèn)統(tǒng)計(jì)
  • |
  • 參考文獻(xiàn)
  • |
  • 相似文獻(xiàn)
  • |
  • 引證文獻(xiàn)
  • |
  • 資源附件
  • |
  • 文章評(píng)論
    摘要:

    為了檢驗(yàn)研制的便攜式作物生長(zhǎng)監(jiān)測(cè)診斷儀的整體性能,在室內(nèi)、室外、田間分別對(duì)作物生長(zhǎng)監(jiān)測(cè)診斷儀的性能進(jìn)行了試驗(yàn)研究。結(jié)果表明,多光譜傳感器具有較高的線性度與精度,線性決定系數(shù)均達(dá)到了0.95以上;傳感器的重復(fù)性與穩(wěn)定性好,其中波長(zhǎng)720nm探測(cè)鏡頭的回程誤差為3.35%,波長(zhǎng)810nm探測(cè)鏡頭的回程誤差為2.22%;儀器的動(dòng)態(tài)穩(wěn)定性良好,在測(cè)試環(huán)境下,太陽(yáng)光源輻照度變化引起的測(cè)量誤差較小,其中波長(zhǎng)720nm探測(cè)鏡頭平均誤差為1.43%;波長(zhǎng)810nm探測(cè)鏡頭平均誤差為1.38%;儀器對(duì)水稻葉層氮含量、葉層氮積累量、葉面積指數(shù)和葉干重的監(jiān)測(cè)性能優(yōu)良,線性擬合決定系數(shù)分別為0.8795、0.8830、0.8596和0.8393;平均測(cè)量誤差分別為6.14%、8. 29%、6.24%和6.19%。

    Abstract:

    Experiments were carried out on the performance of the crop growth monitoring diagnostic instrument. The results showed that multi-spectral sensor had high linearity and precision, and linear correlation coefficient was over 0.95. Sensor with characteristics of good repeatability and stability, the hysteresis error of whose detection lens on 720nm was 3.35%, and on 810nm was 2.22%. And also the dynamic stability of the instrument was well. In the test environment, with the smaller measurement error caused by the solar light irradiation changes, the average error of 720nm detection lens was 1.43% and of 810nm detection lens was 1.38%. The instrument has excellent performance on monitoring leaf nitrogen content, leaf nitrogen accumulation, leaf area index and leaf dry weight , the linear regression correlation coefficient of which were 0.8795, 0. 8830, 0.8596 and 0.8393 respectively and average measurement error of which were 6.14%, 8.29%, 6.24%, 6.19% respectively.

    參考文獻(xiàn)
    相似文獻(xiàn)
    引證文獻(xiàn)
引用本文

楊建寧,張井超,朱艷,姚霞,曹衛(wèi)星,倪軍.便攜式作物生長(zhǎng)監(jiān)測(cè)診斷儀性能試驗(yàn)[J].農(nóng)業(yè)機(jī)械學(xué)報(bào),2013,44(4):208-212,201. Yang Jianning,Zhang Jingchao,Yao Xia,Zhu Yan,Cao Weixing,Ni Jun. Experiments on Performance of Portable Plant Growth Monitoring Diagnostic Instrument[J]. Transactions of the Chinese Society for Agricultural Machinery,2013,44(4):208-212,201.

復(fù)制
分享
文章指標(biāo)
  • 點(diǎn)擊次數(shù):
  • 下載次數(shù):
  • HTML閱讀次數(shù):
  • 引用次數(shù):
歷史
  • 收稿日期:
  • 最后修改日期:
  • 錄用日期:
  • 在線發(fā)布日期: 2013-03-28
  • 出版日期: