    摘要:

    為了提高無閥壓電泵中流管的流阻特性,提出一種新型橢圓組合管結(jié)構(gòu)。該流管為三通結(jié)構(gòu),匯流管是傳統(tǒng)擴(kuò)散/收縮管,分流管是橢圓曲線結(jié)構(gòu)的擴(kuò)散/收縮管。通過數(shù)值模擬,應(yīng)用正交方法優(yōu)化橢圓組合管的結(jié)構(gòu)參數(shù)。設(shè)計選用的匯流管最小寬度d=150μm,流管深度H=150μm,優(yōu)化結(jié)果表明當(dāng)進(jìn)出口壓差為50kPa時,結(jié)構(gòu)尺寸為r=75μm,L=3000μm,θ=7°,γ=80°,a=1000μm,b=450μm的橢圓組合管有最高的正反向流阻系數(shù)比λ。通過MEMS技術(shù)制作出優(yōu)化后的橢圓組合管并進(jìn)行試驗,并與數(shù)值模擬結(jié)果對比。結(jié)果表明:試驗值小于模擬值,壓差在10~100kPa范圍內(nèi),正向流量試驗值與模擬值最大相差12.6%,反向流量兩者最大相差5.3%;壓差為50kPa時,兩者的λ值分別為1.83和1.97,相差7.65%。

    Abstract:

    In order to improve the characteristics of flow resistance in the valveless piezoelectric pump, a micro flow tube called oval composite was presented. It’s a kind of three-way tube, of which branch tube was composed of oval nozzle/diffuser elements and converging tube was composed of traditional nozzle/diffuser elements. In the numerical simulation, the orthogonal optimization was applied to obtain parameters of the proposed tube. The minimum width of converging tube d was 150μm and the depth of the tube H was 150μm. The optimization results showed that when the pressure difference between the inlet and outlet was fixed at 50kPa, the highest coefficient of positive and negative flow resistance λ was achieved with optimization parameters of r=75μm, L=3000μm, θ = 7°, γ = 80°, a=1000μm, b=450μm. Then, the optimized composite tubes were produced though MEMS processing technology and the experiments were carried out and compared with the numerical simulations. The results showed that the experimental value was less than simulated value with pressure difference of 10~100kPa. The positive largest mass flow difference between the experiment and simulation was 12.6%, and the negative was 5.3%. When the pressure difference was 50kPa, λ was 1.83 (positive) and 1.97(negative) with difference of 7.65%

    參考文獻(xiàn)
    相似文獻(xiàn)
    引證文獻(xiàn)
引用本文

鄧志丹,何秀華,楊嵩,李富.無閥壓電泵用橢圓組合管正交優(yōu)化設(shè)計與試驗[J].農(nóng)業(yè)機(jī)械學(xué)報,2013,44(9):284-288,278. Deng Zhidan, He Xiuhua, Yang Song, Li Fu. Orthogonal Optimization Design and Experiment of Oval Composite Tube in Valveless Piezoelectric Pump[J]. Transactions of the Chinese Society for Agricultural Machinery,2013,44(9):284-288,278.