亚洲一区欧美在线,日韩欧美视频免费观看,色戒的三场床戏分别是在几段,欧美日韩国产在线人成

基于CFD正交試驗(yàn)的旋流泵優(yōu)化設(shè)計(jì)與試驗(yàn)
作者:
作者單位:

作者簡(jiǎn)介:

通訊作者:

中圖分類號(hào):

基金項(xiàng)目:

國(guó)家自然科學(xué)基金資助項(xiàng)目(51109093)、“十二五”國(guó)家科技支撐計(jì)劃資助項(xiàng)目(2011BAF14B01)和江蘇省科技成果轉(zhuǎn)化專項(xiàng)資金資助項(xiàng)目(BA2011126)


Optimization Design and Test of Vortex Pump Based on CFD Orthogonal Test
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問統(tǒng)計(jì)
  • |
  • 參考文獻(xiàn)
  • |
  • 相似文獻(xiàn)
  • |
  • 引證文獻(xiàn)
  • |
  • 資源附件
  • |
  • 文章評(píng)論
    摘要:

    為了優(yōu)化旋流泵的水力性能,找出影響旋流泵性能的主要結(jié)構(gòu)參數(shù),采用正交試驗(yàn)方法,選取葉輪外徑D2、葉片數(shù)Z、葉片寬度b2、葉片出口安放角β2、葉片進(jìn)口安放角β1為主要因素,選取L16(45)正交表得到16組方案,由數(shù)值計(jì)算結(jié)果級(jí)差分析初步獲得各因素的較優(yōu)取值范圍,再次進(jìn)行少因素的正交試驗(yàn),通過級(jí)差綜合分析法,探索主要因素對(duì)旋流泵的影響規(guī)律,找到了影響旋流泵性能的主要因素和次要因素,最終得出較優(yōu)方案組合。原型機(jī)和較優(yōu)設(shè)計(jì)方案內(nèi)流場(chǎng)和試驗(yàn)結(jié)果對(duì)比分析表明:旋流泵進(jìn)口處產(chǎn)生兩個(gè)不同程度的回流損失;優(yōu)化方案內(nèi)流場(chǎng)回流損失較少,優(yōu)于原型泵;較優(yōu)方案比原型機(jī)的效率高出4.2個(gè)百分點(diǎn),揚(yáng)程高出10m左右;效率和揚(yáng)程有一定的提高,滿足設(shè)計(jì)要求,驗(yàn)證了正交試驗(yàn)的可行性。

    Abstract:

    In order to acquire the main structure parameters impacting on performance of vortex pump and optimize the performance of the vortex pump, the orthogonal testing method was introduced. Impeller outer diameter D2, blade number Z, width of blade b2, impeller outlet blade angle β2 and impeller inlet blade angle β1 were chosen to be the main factors. So 16 sets of programs with 16 type of impellers were designed according to L16(45)orthogonal table. Optimum value range of each factor was preliminarily obtained through range analysis. Quadratic orthogonal test was conducted to investigate the effects of main factors and acquire the primary and secondary factors of the design parameters on the vortex pump, and an optimization scheme for further design was obtained. The internal flow field and experimental results of optimization scheme were compared with the original model, and it showed that pump inlet produced two back-flows with different degree; the back-flow loss of optimal model was less than that of the original model; the efficiency and the head of optimal model are both higher than those of the original model 4.2 percentage points and 10m, respectively. The improved efficiency and head can meet the design requirements. The orthogonal testing method has some feasibility to the performance optimization of vortex pump.

    參考文獻(xiàn)
    相似文獻(xiàn)
    引證文獻(xiàn)
引用本文

高雄發(fā),施衛(wèi)東,張德勝,張啟華,方 波.基于CFD正交試驗(yàn)的旋流泵優(yōu)化設(shè)計(jì)與試驗(yàn)[J].農(nóng)業(yè)機(jī)械學(xué)報(bào),2014,45(5):101-106. Gao Xiongfa, Shi Weidong, Zhang Desheng, Zhang Qihua, Fang Bo. Optimization Design and Test of Vortex Pump Based on CFD Orthogonal Test[J]. Transactions of the Chinese Society for Agricultural Machinery,2014,45(5):101-106.

復(fù)制
分享
文章指標(biāo)
  • 點(diǎn)擊次數(shù):
  • 下載次數(shù):
  • HTML閱讀次數(shù):
  • 引用次數(shù):
歷史
  • 收稿日期:2013-07-16
  • 最后修改日期:
  • 錄用日期:
  • 在線發(fā)布日期: 2014-05-10
  • 出版日期: 2014-05-10